Home > Fuel Quality Testing
Sort By:
Page of 4
Aqua-Glo Kit - Series V Aqua-Glo Kit - Series V

Series V Aqua Glo measures water (to ASTM D 3240) content of Jet Fuel. Detects presence of free water from 1-12 ppm within 1.5 ppm. The AQUA-GLO® Kit employs this unique approach in the determination of the degree of fluorescence (or water content). NSN #6635002449478. For more information see Bulletin No.86

Aqua-Glo Combination Kit Aqua-Glo Combination Kit

The Series V Aqua-Glo was introduced in 2005 with an entirely new power supply. This power supply is external, automatically switching to work with either 120 VAC or 220VAC, 50/60 Hz.Extreme care has been taken in perfecting a standard that will not deteriorate with age. NSN # 6640011382563 For more information see Bulletin No.86

MiniMonitor Mark II Complete Test Kit MiniMonitor Mark II Complete Test Kit

NSN # 6640010054490.

The MiniMonitor® Kit is used to test aviation fuel for particulate contamination using the procedures described in ASTM D2276/IP216. A measured volume of fuel is passed from a flowing pipe directly through a 0.8 micrometer membrane. The plastic monitor holding the membrane is placed in an aluminum housing. Dirt particles are caught on the membrane which can be visually color rated or weighed for a gravimetric rating.

The new style of carrying case provides a cavity which accepts the assembled kit, eliminating the need to disassemble each time the apparatus is stored.

For more information see Bulletin No. 8.

B-2 Digital Refractometer B-2 Digital Refractometer

A quick, easy method for determining the volume percent (%v.) of anti-icing additive (FSII) in jet turbine engine fuels. Operator error is minimized and the test is faster.

For more information see Bulletin 145.

Apparatus for ASTM Test Method D5452 Apparatus for ASTM Test Method D5452

Gravimetric to ASTM D5452 designed for safety from electrostatic hazards during filtration. For more information see Bulletin No.151

â…“ U.S gallon- In-Tank Sampler ⅓ U.S gallon- In-Tank Sampler

The unique model GTP-9021 was developed specifically to fit through the small gauging found on U.S. Air Force bases where level gauging electric cables are also present. It was important that there be no tangling of our sampler with those cables and that those cables not be damaged. Therefore, the outside diameter is only 3.1 in (79 mm).

For more information see Bulletin No. 115.

Float Tester Float Tester

Water Sump Float Tester for testing the emergency shut down system on aircraft refueling systems. A controlled volume of water is slowly pumped by hand into the filter separator sump. If the emergency shut down system is operating correctly, fuel flow will stop automatically when the level of water in the sump reaches the sensors. For more information go to Bulletin No.63

Float Tester Float Tester

Tester with two wheeled cart, transparent measuring container at top has adjustable level indicator that the operator can see that all of the water that was pumped into the filter separator sump has been recovered. Water filling port is at top see chained plug, overflow pipe carries excess fuel to five gallon slop collector on lower platform. For more information see Bulletin No.63

Meter Monitor US/G Meter Monitor US/G

The meter monitor makes closed circuit membrane testing possible and avoids the need for a measuring bucket and the need to dispose of fuel. For more information see Bulletin No.65

Meter Monitor Liters Meter Monitor Liters

The meter monitor makes closed circuit membrane testing possible and avoids the need for a measuring bucket and the need to dispose of fuel. For more information see Bulletin No.65

Aircraft Refueling Hose Tester Aircraft Refueling Hose Tester

The Gammon Aircraft Refueling Hose Tester is made of non-ferrous materials, designed for periodic testing of jet refueling hose, using jet fuel for pressurizing.
The unit consists of a 10 U.S. gallon (38 liter) aluminum tank (GTP-2234) equipped with a vented fill cap, hand pump (GTP-8076), 0-1000 psi 4.5” face pressure gauge (GTP-281-H), quick disconnect (GTP-1004-4MA), and six feet of 1/4” hose (GTP-8079) to connect to the tester.
For more information see Bulletin No. 79

Flushing Head Valve and Monitor Housing for MiniMonitor Flushing Head Valve and Monitor Housing for MiniMonitor

Flushing head valve and monitor housing used for the MiniMonitor (GTP-172-H) and MiniMonitor Kit (GTP-172).

Hose Assy Hose Assy

Hose Assembly, outlet, for GTP-191 pad holder assembly for the Aqua-Glo unit. For more information see Bulletin No.86

Toggle Valve Toggle Valve

TOGGLE VALVE, 1/8" NPT M X F ALUM. FOR GTP-191

MultiMiniMonitor Assembly Only MultiMiniMonitor Assembly Only

This is the MultiMiniMonitor assembly only, separate from the MultiMiniMonitor kit (GTP-1172).

For more Information see Bulletin No. 8.

MiniMonitor Assembly Only MiniMonitor Assembly Only

This is the MiniMonitor assembly only, separate from the MiniMonitor kit (GTP-172).

The MiniMonitor® is used to test aviation fuel for particulate contamination using the procedures described in ASTM D2276/IP216. A measured volume of fuel is passed from a flowing pipe directly through a 0.8 micrometer membrane. The plastic monitor holding the membrane is placed in an aluminum housing. Dirt particles are caught on the membrane which can be visually color rated or weighed for a gravimetric rating.

For more information see Bulletin No. 8.

Aqua-Glo Pad Holder Aqua-Glo Pad Holder

Aqua-Glo Pad Holder Assembly used with GTP-25 water detector pads (25mm) for more information see Bulletin No. 86

Aqua-Glo Pads Aqua-Glo Pads

The water detector pads are used in the Aqua-Glo Kit to ASTMD 3240, and are produced in compliance with MIL-D-81248 {WP} . Each pad is packaged in an air and moisture proof envelope. NSN # 6640002353820. For more information see Bulletin No.86

Aqua-Glo Series V w/Power Cord and Standards Aqua-Glo Series V w/Power Cord and Standards

Aqua-Glo Water Detector Series V Only with power cord and standards. 120/220 Vac. For more information see Bulletin No. 86

External Power Supply External Power Supply

External Power Supply, 120-240 Vac for Aqua-Glo Series V only

Aqua-Glo Series V Light Assy & Power Supply Aqua-Glo Series V Light Assy & Power Supply

Upgrade kit for the Aqua-Glo Series III to V for more information see Bulletin No.86

Syringe Syringe

SYRINGE, MINIMONITOR/AQUA-GLO

Tweezers Tweezers

Tweezers for the Aqua-Glo Pads. NSN# 6635012329536. For more detailed information go to Bulletin No.86

Calibrated Plastic Bottle Calibrated Plastic Bottle

Calibrated Plastic Bottle 500 ML for Aqua-Glo Kit. For more information see Bulletin No.86

Standards Set Standards Set

Fluorescing and Calibrating Standards Set for Aqua-Glo water detection

ASTM Color Rating Booklet ASTM Color Rating Booklet

Color Rating Booklet used for color rating filter membranes for aviation turbine fuels in accordance with Appendix X1 of ASTM Test Method D2276/IP216.

For more information see Bulletin No. 80.